Key Data Set Information | |
Location | IT |
Geographical representativeness description | Lombardy Region. |
Reference year | 2022 |
Name |
|
Technical purpose of product or process | Recycling of inert waste deriving from construction and demolition activities in a fixed plant. |
Synonyms | Riciclo rifiuti C&D in impianto fisso |
Classification |
Class name
:
Hierarchy level
|
General comment on data set | Dataset developed within the ARCADIA project in the context of the Ph.D. of Federica Carollo (Politecnico di Milano). The dataset relates to the recycling of 1 tonne of mixed construction and demolition (C&D) waste (EWC 17 09 04) in Italy. The dataset is composed of 7-unit processes: 1) avoided the production of natural aggregates (For C1/C2 and C4 use) (Process: Inert natural mix from Lombardy Region); 2) Diesel consumption for waste treatment; 3) Electricity consumption for the waste treatment; 4) Steel-manganese alloy for mill jaws spare parts; 5) Transport of the SRMs produced by the recycling plant (which would be 99.83% of the incoming waste) to the final use; 6) Output of ferrous metals that goes to sorting (Process: Metals, sorting); 7) Transport of ferrous metals to recovery (0.12% are ferrous waste). |
Copyright | Yes |
Owner of data set | |
Data set LCA report, background info | |
Quantitative reference | |
Reference flow(s) |
|
Time representativeness | |
Data set valid until | 2027 |
Technological representativeness | |
Technology description including background system | The C&D waste treatment in recycling facilities consists of a sequence of physical and mechanical steps including crushing, metal separation, sieving and manual/mechanical sorting to remove the impurities such as wood, paper, and plastic. In addition to RAs, other materials flow and residues are outputs of the recycling facilities: - ferrous metals (0.13%): they are sent to a sorting plant and then to recycling for the production of secondary steel; - wood, plastics and other mixed recyclable materials (e.g., cables): their treatment was not included in the LCA because no information was available regarding their recycling process and avoided products; moreover, these fractions should not be present in C&D waste (should be sorted and removed on site before demolition) and their recovery is not the main function of C&D waste recycling plants; - non-recoverable residues (0.17%): they are sent to a landfill for inert materials. Good the Reliability; Very Good the Geographical representativeness; Very Good the Time representativeness; Very Good the Technological representativeness. |
LCI method and allocation | |||||
Type of data set | Partly terminated system | ||||
LCI Method Principle | Attributional | ||||
LCI method approaches |
| ||||
LCA methodology report | |||||
Data sources, treatment and representativeness | |||||
Data cut-off and completeness principles | Exclusion of wood, plastics, and other mixed recyclable materials (e.g., cables) treatment. Exclusion of non-recoverable residues (0.17%) which are sent to a landfill for inert materials. | ||||
Documentation of data quality management | |||||
Data source(s) used for this data set | |||||
Completeness | |||||
Completeness of product model | All relevant flows quantified | ||||
Validation | |||||
| |||||
Compliance Declarations |
Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Commissioner and goal | |
Commissioner of data set | |
Project | Arcadia – PON Governance e Capacità istituzionali 2014-2020 (PhD Project of Federica Carollo). |
Data generator | |
Data set generator / modeller | |
Data entry by | |
Time stamp (last saved) | 2022-12-04T22:40:38.888+02:00 |
Data set format(s) | |
Publication and ownership | |
UUID | 385ff2f0-779c-4d03-a71c-6b8e70c8a7b2 |
Date of last revision | 2017-02-16T16:48:45.683Z |
Data set version | 01.00.000 |
Permanent data set URI | ../processes/385ff2f0-779c-4d03-a71c-6b8e70c8a7b2.xml |
Owner of data set | |
Copyright | Yes |
License type | Free of charge for all users and uses |
Access and use restrictions | Type of license: Open Database Licence (ODbL). |